Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS
Choose a sub category:
JOIST HANGERS FRAMING ANGLES/ANCHORS MENDING PLATES
NAIL PLATES POST ANCHORS / CAPS FENCE BRACKETS
BRIDGING INSULATION SUPPORTS STRAPS
PLYWOOD CLIPS FOUNDATION ANCHORS BRICK/WALL TIES
MISC CONSTR HARDWARE
Sort By:
1
USP Lumber RT3A Double Plate Hurricane/Seismic Anchor USP Lumber HUS26 Double Shear Slant Joist Hanger USP Lumber KST224 Strap Tie
Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Offers double shear nailing. Dimples on hanger allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing. G90 galvanizing finish. Requires 16d nails for installation. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779 and Dade County, FL06-0921.05 codes. Wide strapping with G90 galvanizing finish. Requires (30) 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger USP Lumber KST237 Strap Tie RH Tamlyn PCS716 Plywood Clip
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Wide strapping with G90 galvanizing finish. Requires 1/2" bolts or 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
RH Tamlyn PCS12 Plywood Clip RH Tamlyn PCS1532 Plywood Clip RH Tamlyn PC716 Plywood Clip
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed.
USP Lumber HPAHD22 Foundation Strap Acorn IHW16100 Insulation Support Wire 16 in L USP Lumber NA11-5MC Joist Hanger Nail
Designed to anchor wood framing to poured concrete, foundation straps tie mudsill, and stud simultaneously to the foundation. Single pour edge installation. G90 galvanized finish. Embedment 10". Requires 16d nails for installation. Meets ICC-ES ESR-2787 codes. 10 Gauge - 24-3/4"H1 x 10"H2. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Structurally rated. For use with USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber NA9-5MC Joist Hanger Nail Deckmate 90166 Deck Bench Bracket with Bench Bracket Acorn IHW24100 Insulation Support Wire 24 in L
Structurally rated. For use with USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. You determine the size. Connect with railing brackets with 2x4 and 2x6 lumber to easily add a bench to any size or shape deck. Gain increased seating area while using only 7" of deck space. Assembled unit stands 36"H for deck railing, seat is 17"H. Quick and easy to assemble using basic tools. Includes bench bracket, hardware and instructions. LUMBER NOT INCLUDED. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
USP Lumber RS22-R Coiled Strap RH Tamlyn BT28500SP Corrugated Straight Brick Wall Tie RH Tamlyn BT 22SP Corrugated Straight Brick Wall Tie
Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed.
Acorn IHW16500 Insulation Support Wire 16 in L ANGLE 2X4IN TRIPLE ZINC 12GA  Hopkins 90128 Shelf Link 4 ft L x 2 ft W
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. You can determine the size and configuration, just add 2x4's to the ShelfLinks to make functional and custom shelving in any length, height and configuration. Made of structural resin. Can support spans up to 8'. Includes ShelfLinks, hardware and instructions. LUMBER NOT INCLUDED.
USP Lumber RS16-R Coiled Strap USP Lumber RT7 Double Plate Hurricane/Seismic Anchor USP Lumber JL24 Standard Joist Hanger
Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST12 Strap Tie USP Lumber RT7A Double Plate Hurricane/Seismic Anchor USP Lumber BL Corner Brace
Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge.
Deckmaster DMP125-10 Hidden Deck Bracket Kit Deckmaster DMP175-10 Hidden Deck Bracket Kit Deckmaster DMP100-10 Hidden Deck Bracket Kit
System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip.
ANGLE 2X6IN TRIPLE ZINC 12GA  STRAP TIE 3 X 7IN TRIPLE ZINC Simpson Strong-Tie LSTA Light Duty Strap Tie
Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Medium capacity; requires (20) 10d x 1-1/2" HDG nails for installation. Meets 130 codes. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JL26 Standard Joist Hanger USP Lumber MP34 Framing Angle USP Lumber LSTA12 Light Capacity Strap Tie
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PCP Post Cap USP Lumber NP Truss Mending Plate USP Lumber KST216 Strap Tie
Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Wide strapping with G90 galvanizing finish. Requires (30) 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
Hopkins 90110 Comfortable Flip Top Bench Table USP Lumber JUS28 Double Shear Slant Joist Hanger USP Lumber JUS210 Double Shear Slant Joist Hanger
Make a comfortable, sturdy bench and a table up to 8' long. Just add 2x4 lumber pieces. Flips and locks from a bench to a table in seconds without using tools. Slide lock safely secures and locks in position. Made of maintenance free structural resin. Use only one or slide two Bench Tables together for a full size picnic table. Good for small porches and decks. Assembled unit stands 34"H in the bench position, 31"H in the table position and both with 17.5"H seat. Includes Bench Table legs, hardware and instructions. LUMBER NOT INCLUDED. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber RT5 Double Plate Hurricane/Seismic Anchor USP Lumber FB24-TZ Fence Bracket U-CLIP 2X-2X TRIPLE ZINC
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides stronger fence connections and simplifies fence assembly. Can be installed before posts are set to help ensure uniform spacing and alignment. Requires five 6d HDG fasteners for rails and three 8d HDG fasteners for posts. A clip connects a 2x wood member to the face of another wood member; 20 gauge; G-185 galvanizing finish; requires (6) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included.
Deckmaster GJJ2 Grabber Joist Jaw Hopkins 90158 Workbench Kit USP Lumber JL210 Standard Joist Hanger
Holds up rafters and joists, eliminating the need for two people. Automatically levels the crossmember with the rimjoist or ledger giving the framer a "hands free" position while installing the joist hanger or other connectors. Clamps down on target from the top or the bottom and holds lumber tight. Reusable and made of zinc plated durable steel. For all 2x wood framing or less. Decking, roofing, and flooring applications. Includes 2 joist jaws per package. Create a workbench, worktable or power tool stand. Add 2x4's plywood or particleboard to make a workbench, worktable or power tool stand in any length or width up to 8'L x 4'W. Simple assembly in less than an hour with only powered screwdriver and a saw. Only straight, 90-degree cuts required, no miter or angles. Made of structural resin.  Kit includes: 4 legs, hardware and instructions. LUMBER AND SHELF LINKS NOT INCLUDED. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JL28 Standard Joist Hanger USP Lumber RT Hurricane/Seismic Anchor USP Lumber JUS28-TZ Double Shear Slant Joint Hanger
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
STRAP TIE 3-1/4X16IN TRI-ZINC USP Lumber NP35 Truss Mending Plate USP Lumber PB 2-Piece Split Post Cap
Wide strapping; requires (16) WS15-HDG nails for installation. Meets 110 codes. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber LSTA18 Light Capacity Strap Tie USP Lumber PL4 Protection Plate HANGER RIDGE RAFTER 18 GAUGE
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness. Supports rafter pitches up to 7:12 (30?). Nesting top flange for installation on 2x support beams. Use all specified fasteners. The rafter end at the ridge must be plumb cut to achieve published loads. Optional diamond nail holes can be used to faster RR to end of rafter before settling rafter into place.
USP Lumber RT15 Double Plate Hurricane/Seismic Anchor USP Lumber KST116 Strap Tie USP Lumber JUS24 Double Shear Slant Joist Hanger
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Wide strapping with G90 galvanizing finish. Requires (30) 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST9 Strap Tie USP Lumber T6 T-Post Strap USP Lumber JUS24-TZ Double Shear Slant Joint Hanger
Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber TPP24 Prong Mending Plate USP Lumber EBG Elevated Post Base USP Lumber KNS1 Protection Plate
Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code.
USP Lumber SMP Fence Post Connector USP Lumber MPA1 Framing Angle USP Lumber EPB Elevated Post Base
Reinforcement brackets used to repair rotted or damaged fence posts. Step-by-step instructions labeled onto each. Green corrosion resistant paint finish. 13 Gauge - For 4 x 4 Posts. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber THD410 Medium Capacity Truss Hanger USP Lumber L6 L-Post Strap USP Lumber JA1-TZ Framing Angle
Medium capacity hanger for LVL, LSL and PSL beams; drive bend line nails into header at 45 degrees to achieve listed loads; G90 galvanizing finish. Codes: ESR-1781, ESR-1881, FL821, FL9835, FL13285, Dade County FL 06-0921.05, L.A. City RR 25779 and L.A. City RR 25843. Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
USP Lumber T6-TZ T-Post Strap USP Lumber TPP Truss Mending Plate USP Lumber JUS26 Double Shear Slant Joist Hanger
Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS210-TZ Double Shear Slant Joint Hanger USP Lumber L6TZ L-Post Strap USP Lumber PA(E) 2-Sided Post Anchor
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes.
USP Lumber JUS26-TZ Double Shear Slant Joint Hanger USP Lumber RS150 Coiled Strap USP Lumber BL Corner Brace
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge.
USP Lumber NP37 Truss Mending Plate USP Lumber LSTA24 Light Capacity Strap Tie USP Lumber HUS28 Double Shear Slant Nail
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Offers double shear nailing. Dimples on hanger allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing. G90 galvanizing finish. Requires 16d nails for installation. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779 and Dade County, FL06-0921.05 codes.
USP Lumber RT Hurricane/Seismic Anchor ANGLE 2X-2X TRIPLE ZINC 16GA  USP Lumber MPA1 Framing Angle
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber D Post Anchor USP Lumber SFP30 Fence Post Connector USP Lumber TFL2595 Joist Hanger
Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber BL Reinforcement Corner Brace USP Lumber BP583 Standard Bearing Plate USP Lumber PBS 2-Piece Post Beam Cap
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Designed to meet code requirements for mudsill-to-foundation and stud-to-foundation connections. Two-piece design. Two extended side plates and wraparound post design offers greater lateral resistance. Easy retrofit installations. Designed to work with single, solid-sawn beams, but can be used with built-up beams. Triple zinc finish for ACQ pressure treated lumber. Requires 16d HDG fasteners for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. 18 Gauge - 1-7/16"W x 2-5/16"H1 x 2-3/16"H2 x 3-9/16"L1 x 6-1/2"L2 .
USP Lumber SCA Stair Angle USP Lumber TFL25118 Joist Hanger USP Lumber WE44-TZ Wet Post Anchor
Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge. Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not  for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires (2) 1/2" HDG bolts or (12) HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337, and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
LATE MNDG 13/16X3-1/2IN       USP Lumber PA(E) 2-Sided Post Anchor USP Lumber PBS44-TZ 2-Piece Post Cap 18 ga T
Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Two-piece design. Two extended side plates and wraparound post design offers greater lateral resistance. Easy retrofit installations. Designed to work with single, solid-sawn beams, but can be used with built-up beams. Triple zinc finish for ACQ pressure treated lumber. Requires 16d HDG fasteners for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. 18 Gauge - 1-7/16"W x 2-5/16"H1 x 2-3/16"H2 x 3-9/16"L1 x 6-1/2"L2 .
USP Lumber WBC L Style Wall Brace USP Lumber SCA Stair Angle USP Lumber L12 Medium Capacity L-Strap
L-shaped design for additional strength and rigidity; use with 16" studs; installs one brace at each end of wall section, not exceeding 25 feet in an opposing "V" pattern; use a length of the bracing as a straight web to mark studs; cut a saw kerf 1" deep and insert the bracing web into saw kerf and drive one nail into the top plate; raise the wall section into place and plumb; requires (2) 16d nails and (1) 8d nail for installation; G90 galvanizing finish; 18 gauge. Meets ESR-1831, ESR-1781, FL822, FL13285, L.A. City RR 25836 and L.A. City RR 25843 codes. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation.
USP Lumber L8 Medium Capacity L-Strap USP Lumber PRT2-TZ Pipe Rail Tie USP Lumber PA46E-TZ Post Anchor
Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Use to quickly connect 2" (2-3/8" outside diameter) vertical pipe posts to wood fence rails. Requires (1) 1/4" HDG carriage bolt and nut (included) for tightening pipe rail tie to pipe and (4) 1/4" lag bolts for attaching tie to rail. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes.
USP Lumber ICPL58-TZ Protection Plate USP Lumber JUS210-2 Double Shear Slant Support Joist Hanger USP Lumber TSX24 Truss Spacer
Easy-to-install plates protect plumbing and power/communication wiring from nail or screw penetration. 16 Gauge - 1/16" Thickness. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Fast and accurate spacing guides for trusses, rafters or floor joists. Lightweight and compact, eliminates need to mark layouts on bearing plates, improves installation speed and helps to eliminate spacing errors. Do not rely on TSX  for bracing. Requires one 8d nail per end. 10'L overall; 24" O.C. spacing. 22 Gauge - 5 Sections/Piece.
USP Lumber JUS26-2TZ Double Shear Slant Joint Hanger USP Lumber ST22 Strap Tie USP Lumber PA44-TZDP Post Anchor
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to evaluate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
USP Lumber LSTA36 Light Capacity Strap Tie USP Lumber HUS179 Double Shear Slant Nail USP Lumber THF25925-2 Joist Hanger
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Offers double shear nailing. Dimples on hanger allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing. G90 galvanizing finish. Requires 16d nails for installation. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779 and Dade County, FL06-0921.05 codes. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com.
USP Lumber JUS44-TZ Double Shear Slant Joist Hanger USP Lumber PCM4416-TZ 2-Piece Post Cap 18 ga T USP Lumber EPB Elevated Post Base
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a positive connection for medium-duty, post-to-beam applications. Triple zinc finish for ACQ pressure treated lumber. Requires 16d HDG nails. Meets ICC-ES ESR-1781, FL13285 codes. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber TS Truss Spacer USP Lumber CMST14 Coiled Strap USP Lumber T12 T-Post Strap
Fast and accurate spacing guides for trusses, rafters or floor joists. Lightweight and compact, eliminates need to mark layouts on bearing plates, improves installation speed and helps to eliminate spacing errors. Do not rely on the TS for bracing. Requires (1) 8d nail per end to fasten units to trusses, rafters or floor joists. 2'L overall; 24" O.C. spacing. 20 Gauge - 1 Section/Piece. Enables cut-to-length convenience for a variety of immediate job site needs. Features diamond nail holes to provide nailing options and reduce wood splitting. Heavy 14 gauge steel construction useful in seismic and high wind zones. G90 galvanizing finish. Requires 10d and 16d nails for installation. Meets ICC-ES ESR-1881,  FL821 and L.A. City RR25779 codes. 14 Gauge - 52-1/2' Coil. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation.
TENSION TIE 2-1/2INX16IN      USP Lumber A3 Framing Angle USP Lumber LSSH15-TZ Slope/Skew Joist Hanger
Secures multi-ply studs or posts to mudsill or foundation; nail fastening makes for a convenient connection to studs or posts in cramped retrofit installations; made of 10 gauge steel; with G90 galvanizing finish; use all specified fasteners to attach the strap portion of the connector to the side of stud, post, joist, purlin or beam; secure the base to the concrete or masonry wall with specified anchor bolt. Required fasteners: 10d or 16d x 2-1/2" nails (18 for minimum load requirements, 26 for maximum load requirements) and 1-5/8" anchor bolt. Fasteners are not included. Compliant with ICC-ES code approval listing ESR-3455. Eliminates toenailing and increases strength. Requires 10d x 1-1/2" nails for installation. 1-7/16"W1 X 1-7/16"W2 X 2-3/4"L - 18 GAUGE. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. Connects rafters to ridge beams in vaulted roof structures; field adjustable to meet a variety of skew and slope applications; slopes to any pitch to 45 degrees up or down and skews up to 45 degrees right or left.  For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber SUH44 Joist Hanger USP Lumber THF17112 Joist Hanger USP Lumber JUS46-TZ Double Shear Slant Joist Hanger
Framing connectors for floor systems, deck projects, other joist to header applications, and for light truss applications. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. 16 gauge steel construction. G90 galvanizing finish. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber CBE Column Base USP Lumber PBES 2-Piece Post Cap USP Lumber DTB Deck Tie Bracket
Use for carports, patios, other residential framing. Requires a medium side cover of 3". Embedment 7" with 7-1/2" vertical height from baseplate. Baseplate 3-9/16"W. G90 galvanizing finish. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist over turning (moment loads). Requires either (2) 1/2" HDG  bolts or (12) 16d HDG nails for installation. Nail and bolt load values cannot be combined. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822 L.A. City RR25337 and DSA PA-076 codes. 12 Gauge. Two-piece design. One extended side plate and wraparound post design offers greater lateral resistance. Easy retrofit installations. Designed to work with single, solid-sawn beams, but can be used with built-up beams. Triple zinc finish for ACQ pressure treated lumber. Requires 16d HDG fasteners for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. 18 Gauge - 1-1/2"W x 2-3/8"H1 x 2-3/4"H2 x 3-1/4"L1 x 4-3/4"L2 . Used to reinforce the connection of rail posts to a deck. Also provides lateral strength of deck-to-ledger attachment by securing deck to house framing. Installs with 1/2" anchor bolt (not included) and 8" WS15-GC Wood screws (included). G185 galvanizing finish. Pending IAPMO-ES ER-0200 and FL14500 codes.
USP Lumber C 1-Piece Post Cap USP Lumber NP39 Truss Mending Plate USP Lumber THF25112 Joist Hanger
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com.
USP Lumber THDH26 Heavy Capacity Truss Hanger USP Lumber AC5-TZ Framing Angle USP Lumber JUS28-2TZ Double Shear Slant Joist Hanger
Heavy capacity hanger for LVL, LSL and PSL beams; drive joist nails into header at 30 to 45 degrees to achieve listed loads; G90 galvanizing finish. Codes: ESR-1781, ESR-1881, FL821, FL9835, FL13285, Dade County FL 06-0921.05, L.A. City RR 25779 and L.A. City RR 25843. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber THDH28-2 Heavy Capacity Truss Hanger USP Lumber SKH210L Skewed Left Joist Hanger USP Lumber LSSH210 Slope/Skew Joist Hanger
Heavy capacity hanger for LVL, LSL and PSL beams; drive joist nails into header at 30 to 45 degrees to achieve listed loads; G90 galvanizing finish. Codes: ESR-1781, ESR-1881, FL821, FL9835, FL13285, Dade County FL 06-0921.05, L.A. City RR 25779 and L.A. City RR 25843. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Connects rafters to ridge beams in vaulted roof structures; field adjustable to meet a variety of skew and slope applications; slopes to any pitch to 45 degrees up or down and skews up to 45 degrees right or left.  For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber KCBQ Column Base USP Lumber AC7 Framing Angle USP Lumber D66 Post Anchor
High capacity base fastens with WS Wood Screws. Requires a medium edge distance of 3".  G90 galvanizing finish. Not recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist over turning (moment) loads. Embed column base with bottom of base plate flush to concrete. Requires WS2 Wood Screws (1/4" dia. x 2" long) for installation which are included. Meets ICBO 2725 codes. 7 Gauge. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Deckmaster DMP175-100 Hidden Deck Bracket Kit USP Lumber MP5-TZ Framing Angle Deckmaster DMP125-100 Hidden Deck Bracket Kit
System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies.  Contractor pack includes: 100 brackets, (1200) 10 x 1-1/4" deck board screws, (1100) 8 x 1" joist screws, and a pro bit tip. Use the Contractor pack for large decks. May be field adjusted by hand from 0 to 135 degrees, giving framers and do-it-yourselfers flexibility in applications. Bend angle only once. G90 galvanized finish. 10d HDG nails required for installation. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822, L.A. City RR 25337, DSA PA-06 codes. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies.  Contractor pack includes: 100 brackets, (1200) 10 x 1-1/4" deck board screws, (1100) 8 x 1" joist screws, and a pro bit tip. Use the Contractor pack for large decks.
USP Lumber HD412IF Joist Hanger USP Lumber PA46-DP Post Anchor USP Lumber JNP28 Joiner Nail Mending Plate
Heavy-duty face mount hanger that can be used to support headers, joists and trusses; inverted flange hangers install with wood screws eliminating the need to drill bolt holes simplifying installation; G90 galvanizing finish; requires (22) 16d nails and (10) 10d nails for installation. Meets ESR-1781, FL13285 and L.A. City RR 25843 codes. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to evaluate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge.
USP Lumber HUS26-2 Double Shear Slant Nail
Offers double shear nailing. Dimples on hanger allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing. G90 galvanizing finish. Requires 16d nails for installation. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779 and Dade County, FL06-0921.05 codes.
   
 
1